Connecting to the BA-220 DualBeam
Input/Output connections
The No Read and Good Read output terminals connect through
optional relays. The + Loop and - Loop connections are for an
optional input from a loop detector or other dry contact device.
The +12VDC terminal is an output and provides power to run
accessories such as an external modem. It should not be used for
devices that need more than 500mA of current.
The Ground terminals (both of them) connect to the BA-220
DualBeam electronic circuit ground.
The Wiegand Hold terminal is not implemented and should not be
connected.
Wiegand 1 and Wiegand 0 are the Wiegand communication terminals.
The Wiegand Isolator (Green case) module should be connected
here.
+NO READ
-NO READ
+GOOD READ
-GOOD READ
+LOOP
-LOOP
+12VDC
GROUND
WIEGAND HOLD
GROUND
WIEGAND 1
WIEGAND 0